The Animas Vibe insulin pump and CGM system combines state-of-the-art Dexcom G4 Sensing technology with high-performance Animas pumping. That means it gives you the features Animas® pumps are known for, like waterproof durability¥, fine-tuned dosing and a high-contrast, self-illuminating colour display. It’s also designed to streamline the whole CGM experience for you, while giving you a full-colour view of how your glucose is behaving.
Animas Vibe is designed to give you a more complete picture of your glucose*. In addition, its packed with a unique combination of features designed to help you perform at your best.
*In comparison to MDI
We’re now fully integrated with DexCom G4™ CGM.
It shows your glucose in full-on colour-coded action.
Animas Vibe is the first and only CGM-enabled insulin pump to have a high-contrast colour screen. Coloured trend arrows and lines show where your glucose is headed and how fast. It’s rich information you can see at a glance and along with your fingerstick results, use to help guide insulin adjustments
It’s got up to a week’s worth of convenience built right in.
Animas Vibe is the only CGM-enabled pump that works with a sensor that’s approved for up to 7 days of wear
When it comes to insertion, small is in.
Dexcom G4 Sensor introducer needle is the smallest available in comparison to Medtronic Sof-Sensor and Abbot Navigator.
It’s got simplified calibration rules.
Twice-daily calibration aligns your fingerstick reading with your CGM system so the values correspond. Dexcom G4 Sensors can be calibrated any time when glucose reading is between 2.2 and 22.2 mmol/L*
*Calibration must be taken at least once every 12 hours.
It’s completely tuned into you.
Colour-coded trend lines (blue, red, or green) indicate that glucose levels are low, high, or within the target range relative to the low and high alerts set in the pump. Our customizable alerts can tell you when your going high or low, as well as an added non-adjustable hypo safety alert set at 3.1 mmol/L for extra peace of mind
Accuracy is practically its middle name.
The Dexcom G4 Sensor has excellent overall accuracy and excellent accuracy in the hypoglycemic range (40-80 mg/dL or 2.22-4.44 mmol/L).†
It gives you Diasend®—for the bigger CGM picture.
In your daily life, Diasend® lets you upload your Animas® Vibe™ and meter data.‡ It stores this information on the secure Diasend® web site and also sorts it into charts and graphs, so you can review how you’re doing and share it with your healthcare professional—even between appointments.**
*You must confirm your glucose with a fingerstick test before taking action.
† 60 patients were followed for 7-days while wearing the Dexcom G4™ Sensor. The sensor was calibrated after the first hour and then approximately every 12 hours thereafter using manual entry SMBG from a OneTouch® Ultra2 meter
‡You’ll need to install the Diasend® Uploader in order to upload your data to your Diasend® account.
**Diasend® is compatible with PCs running Microsoft® Vista®, Microsoft® Windows® XP, Windows® 7 and Apple computers running MAC OS® 10.5.7 or later
¥DexCom G4™ Transmitter is waterproof up to 2.4 meters for 24 hours
Intended Use
The Animas® Vibe™ Insulin Pump and CGM System (Animas® Vibe™ System) is indicated for continuous subcutaneous infusion of insulin for the management of insulin-requiring diabetes. The Animas® Vibe™ System is also a glucose-monitoring device indicated for detecting trends and tracking patterns in adults (age 18 and older) with diabetes. The Animas® Vibe™ System is intended for use by patients at home and in health care facilities. The Animas® Vibe™ System is indicated for use as an adjunctive device to complement, not replace, information obtained from standard home glucose monitoring devices. The Animas® Vibe™ System aids in the detection of episodes of hyperglycæmia and hypoglycæmia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions. Interpretation of the Dexcom® CGM results should be based on the trends and patterns seen with several sequential readings over time.
CONTRAINDICATIONS:
The CGM Sensor and Transmitter must be removed prior to Magnetic Resonance Imaging (MRI). Use of Paracetamol-containing medications while the CGM Sensor is inserted may affect the performance of the CGM.
WARNINGS:
The CGM is not designed to replace a blood glucose meter. The CGM must be used with a blood glucose meter. You must take a fingerstick test with your BG meter and use that BG value to make any insulin or treatment decisions. Insulin dosing decisions should not be based solely on results from the CGM. Symptoms related to low or high blood glucose levels should not be ignored. If you have symptoms of low or high glucose, use your blood glucose meter to check the CGM results. You should update the CGM’s calibration every 12 hours at a minimum. CGM Sensors may fracture on rare occasions. If a CGM Sensor breaks and no portion of it is visible above the skin, DO NOT attempt to remove it. Seek professional medical help if you have symptoms of infection or inflammation—redness, swelling or pain—at the injection site. If you experience a broken CGM Sensor, report this to Customer Support or your local Animas distributor. CGM is NOT APPROVED For Use in children or adolescents, pregnant women or persons on dialysis. The safety and effectiveness of the CGM has not been evaluated for Sensor Probe insertion sites other than the abdomen. For important safety information about pump therapy and use of the Animas® Vibe™ insulin pump, please consult with your healthcare provider and the Animas® Vibe™ Owner’s Booklet.<\p>
Contact Animas at: UK: 0800 055 6606 or Ireland 1800 812 715. Or online at www.animascorp.co.uk for detailed indications for use and safety information